Learn More
Thermo Scientific™ TMT™ Elution Buffer and Anti-TMT Resin
For enhanced enrichment, use Thermo Scientific TMT Elution Buffer with Immobilized Anti-TMT Resin for peptides that have been chemically labeled with Tandem Mass Tag (TMT) Isobaric Label Reagents for multiplexed protein quantitation using tandem mass spectrometry.
118.00€ - 826.00€
Especificaciones
Línea de productos | TMT™ |
---|---|
Etiqueta o tinte | Etiquetas Tandem Mass Tag™ (TMT) |
Material de partida | Lisado celular |
Método de detección | Espectrometría de masas |
Paso del flujo de trabajo | Etiquetado de proteínas |
Código de producto | Marca | Cantidad | Tipo de producto | Precio | Cantidad y disponibilidad | ||||
---|---|---|---|---|---|---|---|---|---|
Código de producto | Marca | Cantidad | Tipo de producto | Precio | Cantidad y disponibilidad | ||||
13444289
|
Thermo Scientific™
90104 |
20 mL | TMT™ Elution Buffer |
118.00€
20 ml |
Por favor, inicie sesión para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo. | ||||
11532591
|
Thermo Scientific™
90076 |
6 mL | Immobilized Anti-TMT™ Antibody Resin |
826.00€
6 ml |
Por favor, inicie sesión para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo. | ||||
Descripción
Tandem mass tag (TMT) isobaric label reagents are used for multiplexed protein quantitation using tandem mass spectrometry. Immobilized Anti-TMT Resin is designed to effectively capture and enrich peptides or proteins labeled using any TMT reagent. Anti-TMT Resin and TMT Elution Buffer are effective for reducing sample complexity, improving dynamic range, and studying cysteine modifications such as S-nitrosylation, oxidation, and disulfide bonds of protein samples labeled with iodoTMT reagents.
Tandem mass tag (TMT) reagents are used to chemically label proteins in different samples for multiplexed quantitation using tandem mass spectrometry. Immobilized Anti-TMT Resin contains an agarose-immobilized anti-TMT monoclonal antibody and is effective for capture and enrichment of peptides or proteins labeled using any TMT reagent. This helps simplify otherwise complex samples before LC-MS/MS analysis, especially when the targets for labeling are rare (e.g., cysteine sulfhydryls). Enrichment of labeled peptides by this method results in fewer peptides identified per protein, but can significantly increase the number of unique proteins identified, making it easier to detect and measure low-abundance proteins.
Immobilized Anti-TMT Resin uses our highly specific Anti-TMT Antibody (Cat. No. 90075) to bind peptides labeled with TMT reagents. The antibody is specific for the mass reporter region of the TMT reagents, which allows for enrichment of TMT-labeled peptides regardless of peptide labeling chemistry (e.g., amine-reactive, sulfhydryl-reactive). TMT Elution Buffer is a volatile neutral buffer that competitively elutes captured TMT-labeled peptides. When used in combination with Immobilized Anti-TMT Resin, TMT Elution Buffer provides higher specific enrichment of TMT-labeled peptides compared to acidic or basic elution buffers.
Enrichment features include:
• Specific—uses specific, high-affinity antibody for the TMT structure (Kd >100 pM)
• Compatible—effective for all varieties of TMT reagents (amine-reactive or cysteine-reactive)
• Versatile—use resin with TMT Elution Buffer for optimal sample enrichment
Especificaciones
TMT™ | |
Lisado celular | |
Etiquetado de proteínas |
Etiquetas Tandem Mass Tag™ (TMT) | |
Espectrometría de masas |
Seguridad y manipulación
- TMT Elution Buffer
Palabra de advertencia
- Peligro
Clasificación
- Lesión ocular grave/irritación ocular Categoría 1
- Corrosión o irritación cutáneas Categoría 1A
Indicaciones de peligro
- H314-Provoca quemaduras graves en la piel y lesiones oculares graves.
- H318-Provoca lesiones oculares graves.
Consejos de prudencia
- P260-No respirar el polvo/el humo/el gas/la niebla/los vapores/el aerosol.
- P264-Lavarse concienzudamente tras la manipulación.
- P280-Llevar guantes/prendas/gafas/máscara de protección.
- P301+P310-EN CASO DE INGESTIÓN: Llamar inmediatamente a un CENTRO DE TOXICOLOG A/médico/.
- P303+P361+P353-EN CASO DE CONTACTO CON LA PIEL (o el pelo): Quitar inmediatamente todas las prendas contaminadas. Aclararse la piel con agua/ducharse.
- P304+P340-EN CASO DE INHALACIÓN: Transportar a la persona al aire libre y mantenerla en una posición que le facilite la respiración.
- P305+P351+P338-EN CASO DE CONTACTO CON LOS OJOS: Aclarar cuidadosamente con agua durante varios minutos. Quitar las lentes de contacto, si lleva y resulta fácil. Seguir aclarando.
- P310-Llamar inmediatamente a un CENTRO DE TOXICOLOG A/médico/.
- P405-Guardar bajo llave.
- P501b-Eliminar el contenido/el recipiente en conforme a la reglamentación local/regional/nacional/internacional.
Otros peligros
- MIXTURE LIST-Contém: triethylamine, acetic acid
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.